AIKO / DUAL GLASS

NEOSTAR 2P+48w 500W Dual-Glass Monofacial

AIKO-A500-GRH48Dw

470–500 W STC

1762 × 1134 × 30 mm
N-Type ABC · up to 25% family efficiency

Manufacturer PDF is marked Draft. Check final revision before order.

Exact PDF linked from manufacturer product page. Electrical values are STC only; NOCT and BNPI columns excluded. Cover visibly marked Draft (image, absent from extracted text). Manufacturer PDF: check final revision before order. Dual-glass monofacial, not MCE54Mw mono-glass.

Back to Products

MANUFACTURER DOCUMENTATION

Technical Specifications

Family values must not be mixed with another model, glazing construction or document revision.

Source-matched module family
Manufacturer modelAIKO-A500-GRH48Dw
Power family (STC)470–500 W
Cell technologyN-Type ABC
Glass constructionDual glass
Dimensions1762 × 1134 × 30 mm
Maximum family efficiency25%
Weight24.2 kg
Front material2.0mm coated semi tempered glass
Rear material2.0mm semi tempered glass
Number of cells96
FrameBlack anodized aluminum
Weight tolerance (%)3
Output cable4 mm2 (IEC), 12 AWG (UL); +/-1200 mm
ConnectorsOriginal MC4-EVO2A
Packaging37 modules per pallet / 222 modules per 20'GP / 962 modules per 40'HC
Temperature coefficient of Pmax (STC)-0.26 %/degC (STC)
Maximum system voltage1500 V DC
Maximum static loadFront: 5400 Pa; back: 2400 Pa (maximum static loading)
Electrical characteristics at STC — linked manufacturer revision
Power (W)Voc (V)Isc (A)Vmp (V)Imp (A)Efficiency (%)
4703516.4330.7415.2923.5
47535.1916.5230.915.3723.8
48035.3316.6331.0515.4624
48535.5716.7131.1915.5524.3
49035.7216.7931.3515.6324.5
49535.8616.931.5115.7124.8
50036.0416.9831.6515.825

Specifications are based on the linked manufacturer datasheet. Availability, certifications for the destination market, warranty and final commercial terms are confirmed upon quotation. Bifacial rear-side gain is not STC nameplate power. Suntis uses manufacturer materials as an authorized distributor, as confirmed by the owner. Mechanical loads are manufacturer datasheet test ratings, not project-specific structural design values.